Basic Info
  • Accuracy: <±0.1g
  • Application Area: Widely
  • Application: Force Measurement
  • Material: Stainless Steel
  • Power Supply: 10-33V DC
  • Warranty: 12months
  • Check Weight Range: >20000g
  • Type: Check Weigher Combination
  • Product Name: Weight Sensor
  • Measuring Range: as Customer Request
  • Size: Small
  • Certificate: RoHS
Product Description

 Weight sensor

 

 

Performance characteristics:
1.Elastomer adopt international popular plate ring or dual pore structure forms;
2.The bearing connection of internal and external thread.Has the yaw, lateral resistance, high          precision, stable performance;
3.Applied to various range of electronic scale, hopper scale, belt scale, and the electronic load         system.Easy installation and use.
4.Welding seal
5.With internal thread connection

 

 

Rated LoadL1L2L3MD1
 100101.569M16×1.5Φ87
0.5,0.7t,1t9577.561M16×1.5Φ59
1.5,2t10577.566M20×1.5Φ59
3,4t1259183M24×1.5Φ75
5,6,7t150101.5112M24×1.5Φ75
10,15,20t160113104M36×3Φ94
30,40,50t200145150M42×3Φ120
60,80t240160175M64×3Φ150

 

 

 

 

Rated Output

2.0mV/V ±0.1%

Zero Balance

±1% of rated output

Creep after 30 minutes

±0.03% of rated output

Nonlinearity

±0.03% of rated output

Repeatability

±0.03% of rated output

Temp. effect on output

0.002% of applied output/ºC

Temp. effect on zero

0.002% of applied output/ºC

Safe Temp. Range

-10ºC to + 70ºC

Temp. Compensated

-10ºC to + 40ºC

Safe Overload

150%

Input Impedance

387 ohm ± 20 ohm

Output Impedance

350 ohm ± 5 ohm

Rated Excitation

10V DC/AC

Maximum Excitation

15V DC/AC

 